Ennis Chimney Experts

Find the Part That Stopped the Pellet Stove

Already Have a Quote?

The Work, in Short

Pellet stoves are often written off when one part has quit. We test the auger motor, igniter, both fans, the sensors and the board, clear ash from the burn pot and the exhaust path, and replace only the part that fails its test. Where a stove is past saving or its parts are scarce, we price a replacement beside the repair so you can weigh them.

Auger motor and feed tested under load
Igniter and safety sensors metered
Fans cleaned and listened to for wear
Exhaust path and vent joints cleared
Repair and replacement priced side by side

How a pellet stove fails

A pellet stove has more in common with a furnace than with a fireplace. Pellets drop from a hopper into a feed screw, the screw delivers them to a burn pot, an igniter lights them, one fan pulls air through the fire and out the vent, and another blows heat into the room. Between them sits a circuit board that reads a few switches and kills the fire if one reports trouble. So most failures come down to a single part, and the symptom points to which. No ignition at all often means a dead igniter or a feed screw jammed with fines. A fire that dies a few minutes in usually means a dirty burn pot, a blocked vent, or a switch that thinks the draft has gone. A lazy fire that blackens the glass is usually short of air. We test each possibility in order and tell you which one it is, rather than replacing parts until the stove happens to run.

Dirt is behind many pellet stove calls. Pellet ash is fine, and it settles wherever air moves slowly: the pot, the passages behind the firebox walls, the elbows of the vent. A stove run all winter without a proper clean ends up choking its own air supply. We clear the ash from the stove and the vent run, check the gaskets on the door and the ash pan, and look at the small tube feeding the pressure switch, which clogs and tells the board there is no draft. If a part has failed, we tell you which, whether it is still made, and what it costs to fit. If the stove is old and its board or motors are no longer supported, we say so and set out the options. Pellet stove repairs have no fixed price on this site; the figure follows the part. For owners in Whittier, the call usually comes in the first cold week, after the stove has sat unused since spring.

Repair or replace, and what a second look checks

Pellet stoves that have been told to retire often come to us for a second look. Sometimes the advice is right: a firebox cracked through, a heat exchanger rusted out, a control board for a model no longer made. Sometimes the stove needs a cleaning, a gasket and a new igniter, and has years left in it. We tell you which, with what we found and why. If the stove is worth keeping, the notes list the parts and the price for fitting them. If it is not, we explain whether a new pellet stove, a gas insert or a wood stove suits the space and the venting already there. Venting matters for any choice: pellet vent pipe is its own type, and a stove exhausting into an old masonry chimney often needs a liner to draft properly. We check that on every visit, because a stove that is fine on its own can still be let down by its vent.

When you book, the useful details are the name on the stove's label, the moment it fails (at start-up, a few minutes in, or after an hour) and whatever the display reads. That lets us bring parts for the common faults on that model. While we are there we listen to the feed motor and the room fan for wear, since a bearing that has started to squeal tends to quit in the middle of winter. If an earlier technician left a note or a quote, have it to hand and we will look at their finding first. We cover Whittier, Norwalk and the surrounding towns. When the stove runs again, we watch it through a start-up and several minutes of steady burning, so you see the flame and the ash pattern with us before we leave, and you know what a healthy burn looks like on your own stove.

How Ennis Chimney Experts Works

Photo First

No finding without a picture of it

Now, Later, Never

Repairs ranked so you can plan the spend

Figures on Paper

A written scope before any tool comes out

Your Earlier Quote

Read side by side with what we find

Related Jobs

Chimney Sweep

Flue brushed clean to the cap, then the bare tile checked, so heavy soot is never mistaken for damage.

Open →

Chimney Inspection

An NFPA 211 Level 1 or Level 2 visit that tests someone else's findings against what the chimney really shows.

Open →

Chimney Repair

Repairs scoped from what the chimney shows, not from a scare: cracked tile, open joints, a split crown, loose brick.

Open →

Fireplace Inspection

Firebox, damper, hearth and surround examined from the room, for a fireplace someone has already called unsafe.

Open →

Fireplace Repair

Firebrick, refractory panels, dampers and hearth faults repaired once we agree which ones really need it.

Open →

Chimney Level 2 Inspection

Video of every flue joint, plus the attic and crawl space, booked when an inspector's note asks for further evaluation.

Open →

Chimney Cap Installation

A cap that fits the flue and the roof, chosen after we see whether the old one failed or only looks tired.

Open →

Chimney Flashing Repair

The roof joint at the chimney traced for water first, so flashing is only replaced when flashing is the leak.

Open →

Chimney Masonry Repair

Mortar, brick and crown damage sorted into what is failing now and what is only weathering.

Open →

Chimney Rebuilds

A rebuild proposed only when repair cannot hold, with the photos that prove it and a clear line where new brick begins.

Open →

Fireplace Cleaning

Ash, soot and stained glass cleaned from the room side, with a straight word on whether the flue is due a sweep too.

Open →

Gas Fireplace Cleaning

Burner, pilot, logs, glass and vent cap cleaned on a gas unit, with a leak test before the cover goes back on.

Open →

Gas Fireplace Repair

Gas unit faults found with a meter before parts are ordered, so a quote for a new valve gets checked first.

Open →

Fireplace Remodel

A new face, mantel or hearth planned around a firebox we have checked first, so the finish is not built over a fault.

Open →

Fireplace Inserts

Gas or wood inserts fitted after a camera look at the flue, so the liner and the size are decided on evidence.

Open →

Wood Stove Repair

Door seals, baffles, air tubes and firebrick put right on a wood stove, unless the body itself has cracked.

Open →

Gas Logs

Gas log sets matched to the firebox and the flue, with the gas line and valve fitted and leak tested.

Open →

Chimney Seismic Retrofit

Quake bracing, straps or a lighter top for a brick chimney, scoped after we see how loose the upper stack is.

Open →

Chimney Crown Repair

A cracked crown sealed or recast, depending on how deep the cracks run once we have looked from the roof.

Open →

Dryer Vent Cleaning

The dryer duct cleared from the machine to the outside hood, with airflow measured before and after.

Open →

Chimney Liner Installation

A stainless liner fitted where the camera shows cracked tile or a new insert needs one, matched to what it serves.

Open →

Chimney Leak Repair

Water at the chimney traced to its entry point before a repair is chosen, since the obvious suspect is often wrong.

Open →

Chimney Waterproofing

Repellent for porous brick, offered only when the mortar, crown and flashing would not just leak around it.

Open →

Chimney Damper Repair

A damper that sticks, rattles or leaks air repaired or replaced, once we know which part actually failed.

Open →

Chimney Chase Cover

A stainless top made for a framed chimney whose old cover has rusted, sagged or started dripping inside.

Open →
Book a Second Look